Devilink FT

Technical Specification

Operation voltage: 180-250 VAC, 50/60 Hz
Standby power consumption: Max. 1W
Relay:
- Resistive load: 230V ~ 15A / 3450W
- Inductive load: cos φ = 0.3 Max. 4A
Sensing values:
- 0˚C 42 kOhm
- 20˚C 18 kOhm
- 50˚C 6 kOhm
Regulation: PWM
Ambient temperature:C 0˚ to +30˚C
Sensing unit: NTC 15kOhm at 25˚C
Sensor failure monitoring: The thermostat has a built-in monitoring circuit, which will witch off the heating if the sensor is disconnected or short-circuited
Transmission frequency: 868.42MHz
Transmission range: in normal buildings up to 30m
Transmission power: Max. 1 mW
IP class: 31
Dimensions: (L/W/D) 85x85x21 mm

DEVILINK™ FT

devilink™ FT is the device that switches the heating element on and off.

It can be connected to an underfloor sensor to give a more precise measurement of the floor temperature.

devilink™ FT is built on the devireg™ 530 series. It has an LED indicator, which indicates whether the relay is on or off..

Where to BuyDownloads