Technical Specification

Temperature setting

+5º to +55ºC

Voltage

180-250 V ~ 50/60 Hz

Load

250 V ~ 10 A
Inductive load 1 A
Indicator LED diode
Surrounding thermostat temperature -10º to +45ºC
IP Class IP 20
Type of sensor room sensor with NTC; 15kΩ / 25ºC
Thermostat dimensions Width 36mm to 72mm

Additional Information

DEVIREG 751 754

REGULATOR

devireg™ 700 series is primarily used regulate an accumulating heating system or in other applications where it may be advantageous to utilise low-tariff electricity, according to outside temperature and the “quantity” of stored heat.

This series is electrical thermostats used for DIN rail mounting. The maximum load of the relay is 10 amp. (2500 W by 250 V).

The devireg™ 751-754 are all slave units, which controls different rooms.

• devireg™ 751 controls one room
• devireg™ 752 controls two rooms
• devireg™ 753 controls three rooms
• devireg™ 754 controls four rooms

devireg™ 751-754 units can only be operated in connection with the devireg™ 700.

The temperature in the room can be regulated up and down individually according to a percentage deviation from “normal”. This can be done for periods during either the day or night.

The maximum temperature in each room can be set from the slave units.

Where to BuyDownloads

Product Features
  • DIN rail mounting
  • Accumulating heating systems
  • Master/slave connection – one master can control up to 400 different rooms/zones.
  • Low tariff system

Domestic Applications
  • Heating a Conservatory
  • Total underfloor heating for your home

Professional Applications