Temperature setting |
-10º to +10ºC |
Voltage |
180-250 V ~ 50/60 Hz |
Load |
250 V ~ 16 A /10 A |
| Inductive load | 3 A |
| Switch | NO/NCs |
Hysteresis |
0,4ºC |
| Indicator | LED diode |
| Surrounding thermostat temperature | -10º to +50ºC |
| IP Class | IP 20 |
| Type of sensor | wire sensor with NTC; 15kΩ / 25ºC |
| Thermostat dimensions | Width 36mm |
-10°C TO +10°C
devireg™ 330 series covers 5 different temperature areas.
devireg™ 330, -10° to +10°C, is often used for frost protection or cooling.
The frost protection system can be used for stairs, garages, roof gutters, traffic areas, pipes (trace heating) etc.
devireg™ 330, -10° to +10°C should always be connected with a wire sensor place in the area of heating/cooling.
Please note that the set back function is not available in this version of devireg™ 330.
Please note when connected for cooling the maximum load of the relay is 10 amp. (2500 W by 250 V).
| Product Features | |
|
| Domestic Applications | |
|
| Professional Applications | |
|